Tracing Device & Measuring Instrument |
 |
|
 |
 |
Uninterruptible Leak Point Tracing Device |
| ■ |
Detection of leak points under uninterrupted power conditions |
| ■ |
Detection of leak points (places) in pressure and earth phases through the signal injection method. |
| ■ |
Easy detection of leak points by simply touching wires or equipment with the receiver. |
|
 |
 |
Wired Route Tracing Device (With an Earth-Leakage Point Locating Function) |
| ■ |
Locating of earth-leakage points (with the power stopped) |
| ■ |
Tracing of breakers and wired routes both in live lines and dead lines |
| ■ |
Circuit voltage indicating function <100V, 200V or 400V is judged by the transmitter atone.> |
| ■ |
Conductivity checking function <Conductivity is checked by inserting the attached cord with a test lead bar into the receiver.> |
| ■ |
Easy judgment by sound and light. |
|
 |
 |
Wired Route Tracing Device |
| ■ |
Checking without cutting power because breakers can be traced in live lines |
| ■ |
Easy assessment by sound and light. |
|
 |
 |
Wired Route Tracing Device
(Two-Way Between Power Supply Side And Load Side) |
| ■ |
One person can easily check the load-side (distribution board side)connections from the power supply side (transformer side) both in live lines and dead lines. |
| ■ |
Tracing on the power supply side can also be performed from the load side. |
| ■ |
Easy assessment using sound and light. |
|
 |
 |
Low-Voltage Phase Sequence Indicator |
| ■ |
Simply connect the lead wire clips to a main circuit so that the phase sequences and open phases can be easily checked. |
| ■ |
This lightweight (130g) and compact (28x60X100mm) checker is pocketable. |
| ■ |
Since the connections between the lead wires and main unit are safely constructed so that the live side is a plug-socket type, live parts are not exposed even if the socket is disconnected by chance. |
| ■ |
Lamp indication of measurement results allows reliable judgment. |
| ■ |
The maul unit requiring no batteries for measurement and indication. is economical. At check time, however, circuit voltage needs to be applied. |
|
 |
 |
Harmonic Tracing Device |
| ■ |
This lightweight handy type is convenient for carrying and simple to handle! (Weight: approx. 310g) |
| ■ |
The presence or absence of harmonics can be scanned safely and accurately on high-voltage and lbw-voltage equipment in live lines. |
| ■ |
The second to 40th harmonic current content and total distortion factor are calculated by 512-point fast-Fourier-transform, and are displayed and stored in memory. (Up to 40th harmonic current can be scanned in a few seconds.) |
| ■ |
Fast-Fourier-transform calculation is optimized by setting to 50 or 60Hz commercial frequency with the frequency selector switch. |
|
 |
|
 |