Explosion-proof type control switches(Aluminum Alloy Model)

HPW

Explosion-Proof Control Switches
(Aluminum Alloy Model)

Aluminum alloy explosion-proof control switches with explosion protection ratings of d2G5 and d3aG5.

※ Electrical Equipment Explosion-Proof Design Standard (Japan)

  

Model type

Type Material Hazardous location Explosion-proof construction
EPS・EPW・EDW Aluminium alloy type Applicable in hazardous locations class 1 and 2 d2G5
HPS・HPW d3aG5
  

Specifications

                 
Explosion-proof construction Explosion-proof Explosion-proof(Hydrogen gas correspondence)
Type EPS・EPW・EDW HPS・HPW
Explosion-proof performance d2G5(division 1 and 2 area) d3aG5(Water gas and Hydrogen area)
Water-proof performance Explosion-proof for outdoor(technical guide RⅡS-TR-79-1)
Material(case) Aluminium alloy model
Rated insulation voltage 250 VAC,250 VDC
Insulation Resistance More than 5 MΩ(by 500 VDC megger)
Withstand voltage 1500 V for 1 minute
Standard service condition
(technical guide RⅡS-TR-79-1)
Sea level:up to 1000 m
Ambient temperature:-10 ℃ to 40 ℃
Relative humidity:45% to 85%
Painting color Munsell No.N7 for outer face
                 

Dimensions

 

Specifications(control unit)

  Learn more
             
Meter※1Ammeter 60 mm square, 3-times scale, with a red pointer A or /5 A with CT rate
(But, it's direct retirement possible to 30 A.)
Voltmeter 60, 150 V or 300 V
Push-button switch※2 ※3
(type:PB-H11)
Rated current 10 A
Operating current 220 VAC-5 A 110 VDC-1.3 A(lagging load)
Color Standard:Black(on)-Red(off)
By request:Red(n)-Green(off)
Letter ON-OFF
Contact ON・・・1NO and 1NC  OFF・・・1NO and 1NC
Changeover switch
(type:TS-H11)
Notch 2 or 3
Rated current 10 A
Operating current 220 VAC-5 A 110 V-1.3 ADC(lagging load)
Color Black
Letter Standard:REM-DIR, AUT-MAN, AUT-OFF-MAN
By request:No.1-No.2、AUT-MAN
Contact 1NO and 1NC
Indicating lamp Bulb LED
Color Red, green, orange, white or clarity
Voltage 100 VAC,110 VAC,200 VAC,220 VAC
100 VDC,110 VDC,200 VDC,220 VDC

※1 It's possible to manufacture DC ammeter, a DC voltmeter and a rev counter.

※2 "OFF" locking device

ーStandardー

Push-button has an "OFF" locking device to prevent maloperation. For locking, push-turn 90° to right or left side.

ーBy requestー

Padlocking device will be provided, where required. For padlocking, though the locking plate on the push-button switch then apply the padlock into the hole of the locking plate.(Pad lock general purpose is applicable.)

※3 Protection cover

To prevent the button form adhesion and penetration of dust and foreign matters and from prenetration of seawater.
Material:EPDM Color:gray


・Wiring, operation, maintenance, and inspections of these products must be performed by personnel with specialized knowledge and skills in the installation of explosion-proof electrical equipment and related regulations.
・For installations in hazardous locations, please check the applicable hazardous area classification. The hazardous areas in which products may be installed will vary depending on the specific model.
・Please note that specfications, dimensions, etc., are subject to change without prior notice.

For installation of explosion-proof electrical equipment

Prior to installed of explosion-proof electrical equipments, careful study should be made on the following recommendations.
1. To prevent explosions or files caused by the electrical equipments, every effort should be made, as a prerequisite, to minimize possible danger of explosion at a location where they are to be installed.
2. The electrical equipments should be installed at a location with a minimum posibility of explosion. In case, however, they are unavoidably installed at a hazardous location where explosion is expected, it should be limited to a minimum extent.
3. The explosion-proof electrical equipments to be installed should be the products that have been proved to fully meet he requirements.


Classofication of danger class

Study the sorts of inflammable gas or steam present at a location where the electrical equipments are to be installed in order to determine the explosion class and the firing degree. Then, determine the hazardous locations according to the degree of danger of the locations where the electrical equipments are to be installed. The explosion-proof electrical equipments may be selected on the basis of the determination of explosion class, firing degree and hazardous locations.
The danger class of explosive gas is determined by the firing degree and explosion class.

Firing degree Firing point
G1
G2
G3
G4
G5
over 450 ℃        
over 300 ℃ up to 450 ℃
over 200 ℃ up to 300 ℃
over 135 ℃ up to 200 ℃
over 100 ℃ up to 135 ℃


Explosion class Minimum clearance which permits flame running at 25 mm.
1
2
3
over 0.6 mm
over 0.4 mm up to 0.6 mm
up to 0.4 mm


Classofication example of explosive gases

  G1 G2 G3 G4 G5
1 Ammonia
Carbon monoxide
Acetic acid
Propane
Methane
Ethanole
Amyl Acetate-iso
1-Buthanole
Butane
Acetic anhydride
Gasoline
Hexane
Acetaldehyde
Ethylether
 
2 Coal gas Ethylene
Ethylene oxide
 
3 Water gas
Hydrogen
Acetylene  

Classification of hazardous locations

The areas of possible danger or to be dangerous atmosphere are classfield into class 0, class 1 and class 2 depending upon the dangerous time and frequency of occurrence of danger.

Class 0・・・Where dangerous density of explosive gas continues or is held for a long time above the lower limit of an explosion.

Class 1・・・Where a dangerous atmosphere is expected to be present under normal state.

Class 2・・・Where a dangerous atmosphere is expected to be present under abnormal state.


Type of explosion-proof construction

The explosion-proof construction is designed to protect the equipment in use at a hazardous location and can be divided into many different types including pressure-resisting explosion-proof(d), oil-immersed explosion-proof(o), internal pressure-resisting explosion-proof(f), increased safety explosion-proof(e), substantial safety explosion-proof(i), special explosion-proof(s) and other varying types. Out of them, the following construction types are employed in the explosion-proof electrical equipment introduced in this paper.

※ Pressure-resisting explosion-proof type(d)
  This is of a totally enclosed construction, and should an explosion take place inside the enclosure, the enclosure resists the resultant pressure eliminating a danger of igniting an explosive gas outside.
※ Increased safety explosion-proof type(e)
 This is of the construction which is particularly provided with increased safety on its construction or temperature rise, in order to prevent sparking arcing and overheating on those parts which should not essentially generate them.